Singapore NUS team develops clothing that monitors heart and lung sounds

The washable, wireless system was tested on heart failure patients and newborns, and could support longer-term monitoring after hospital discharge.

Singapore NUS team develops clothing that monitors heart and lung sounds Pixabay

Singapore researchers have developed clothing that can wirelessly monitor heart and lung sounds, potentially helping clinicians track patients for longer after they leave hospital. The system, created by researchers at the National University of Singapore (NUS), incorporates the listening function of a stethoscope into everyday garments.

The all-fibre wireless auscultation system, or FiWAS, uses hair-thin sensor fibres woven into clothing. Its microphones detect small vibrations through contact with the body, while flexible electronics process the signals and send them by Bluetooth to a phone or computer. Unlike smart watches and rings, which can track vital signs, the system can capture sounds from the heart and lungs that may give doctors clues about conditions such as turbulent blood flow or fluid in the lungs, NUS said.

The researchers say FiWAS could help monitor people at risk of deterioration between hospital visits. Its results so far come from small tests, however, and larger clinical trials are planned.

What the tests found

In collaboration with the National Heart Centre Singapore, the team tested FiWAS on 10 patients hospitalised with heart failure. It recorded heart murmurs, an additional sound known as an S3 gallop, and lung crackles that can indicate fluid accumulation. The system also captured an episode of atrial fibrillation in one patient. Research leader Tural Khudiyev, an assistant professor at NUS’ College of Design and Engineering, said continuous monitoring caught the brief irregular rhythm.

At KK Women’s and Children’s Hospital, the system was incorporated into infant onesies and bedding and used to monitor 20 newborns, including extremely preterm infants born before 28 weeks of pregnancy. Researchers said it captured an episode in which a premature infant’s heart rate slowed. KKH senior consultant Yeo Kee Thai said continuous monitoring could provide clinical data without the sticky pads and wires that may hurt fragile skin or interfere with parents holding their baby.

What happens next

A prototype ran for about 40 hours on a small coin-cell battery. The researchers said the system can be washed and withstand washing-machine and dryer cycles. FiWAS’ sound quality was comparable with current digital stethoscopes, Khudiyev said.

Larger clinical trials with both NHCS and KKH are in the works. They are intended to involve more diverse patients and a wider range of heart and lung conditions. The findings were published in Nature Cardiovascular Research in October. The researchers have not announced when FiWAS might become available for clinical use.

This report draws on information from The Straits Times.

Editorial checks passed Facts, figures and quotes checked against 1 source